Novel X-ray technology improves contrast in soft tissueCompact synchrotron makes tumors visible

Soft tissue disorders like tumors are very difficult to recognize using normal X-ray machines. There is hardly any distinction between healthy tissue and tumors. Researchers at the Technische Universität München (TUM) have now developed a technology using a compact synchrotron source that measures not only X-ray absorption, but also phase shifts and scattering. Tissue that is hardly recognizable using traditional X-ray machines is now visible.

X-ray images have become an integral part of daily medical practice. Bones, for example, absorb large amounts of X-rays because of their high calcium content. This allows them to be differentiated from air-filled cavities like the lungs and surrounding soft tissue. However, because of their very similar absorption coefficients, soft tissue, organs and structures inside organs, like tumors, are hardly discernable from one another using the medical devices deployed in medicine today.

Now a group of scientists headed by Franz Pfeiffer, Professor of Biomedical Physics in the Physics Department Department and the Faculty of Medicine at TU München, have for the first time succeeded in making such soft tissue visible. The scientists used a new kind of X-ray source that was developed only a few years ago.

Compact synchrotron source

Unlike classical X-ray tubes, a synchrotron generates highly focused, monochromatic X-rays. The individual rays all have the same energy and wavelength. In the past, X-rays with these properties could only be generated in large particle accelerators, which have a circumference of at least one kilometer. The compact synchrotron, in contrast, has merely the size of a car and fits into a normal laboratory.

“Monochromatic radiation is much better suited for measuring other parameters, in addition to absorption,” explains Elena Eggl, doctoral candidate at the Chair of Biomedical Physics. “This is because it does not lead to artifacts that deteriorate the image quality.”

The scientists inserted an optical grating into the focused X-ray beam, allowing them to detect even tiniest phase shifts and scattering of the radiation in addition to the absorption of X-rays. The first phase contrast tomography image from a compact synchrotron source was successfully acquired.

Complementary information

The phase contrast, dark field and absorption images made using the new technology have complementary properties. Liquid in tissue that remains indiscernible and, thus, invisible using conventional X-ray tubes, suddenly comes to life. The greatly improved soft tissue contrast of the new X-ray technology could also help make tumors detectable earlier on and enable quick diagnoses – in medical emergencies, for example.

The clarity of the new technology becomes apparent when comparing white and brown fatty tissue. “In a mouse we were able to recognize not only heart, liver and other organs much better, but could even differentiate between brown and white body fat,” says Eggl.

Brown fatty tissue, which occurs mainly in newborns, can support the burning of normal white fatty tissue. It is a relatively new discovery that adults, too, still have brown fatty tissue. Tissue that – as some researchers hope – can be reactivated to help obese people lose weight.

While these experiments were performed using an initial prototype setup of Lyncean Technologies Inc. in California, a significantly improved compact synchrotron source is under construction at the Garching Research Campus. It is part of the “Center for Advanced Laser Applications” (CALA), a joint project of the TU München and the Ludwig-Maximillians Universität (LMU). Eggl and Pfeiffer, in collaboration with colleagues in laser physics at the LMU and the Max Planck Institute of Quantum Optics, hope to further improve the new X-ray technology.

The research was funded by the German Research Foundation via the Cluster of Excellence Munich-Centre for Advanced Photonics (MAP), the European Research Council (ERC, Starting Grant Nr. 240142), the National Institute of General Medical Sciences (USA, Grant R44-GM074437) and the National Center for Research Resources (USA, Grant R43-RR025730). Further cooperation partners included the Helmholz Center NanoMikro at the Karlsruhe Institute of Technology (KIT), the University of Lund (Sweden) and Lyncean Technologies Inc. (USA).

Publication:

X-ray phase-contrast tomography with a compact laser-driven synchrotron source.
Elena Eggl, Simone Schleede, Martin Bech, Klaus Achterhold, Roderick Loewen, Ronald Ruth, und Franz Pfeiffer.
Proceedings of the National Academy of Sciences, PNAS, Early Edition, April 20, 2015. – DOI: 10.1073/pnas.1500938112

Contact:

Prof. Dr. Franz Pfeiffer
Chair of Biomedical Physics
Physics Department / IMETUM
James-Franck-Str. 1, 85748 Garching, Germany
Tel.: +49 89 289 12551 (Office)+49 89 289 12552 (Secr.)
E-mail - Internet

Corporate Communications Center

Technical University of Munich

Article at tum.de

Prof. Franz Pfeiffer und PD Dr. Daniela Münzel am Mini-Synchrotron Munich Compact Light Source.

Miniature particle accelerator saves on contrast agents

The most prevalent method for obtaining images of clogged coronary vessels is coronary angiography. For some patients, however, the contrast agents used in this process can cause health problems. A team at the Technical...

Darstellung der Orientierung der Kollagenfasern innerhalb einer Zahnprobe. Die Einzeldaten wurden mit Röntgenstreuung-CT aufgenommen und daraus eine dreidimensionale Nanostruktur der Probe berechnet. (Bild: Schaff et al. / Nature)

Details from the inner life of a tooth

Both in materials science and in biomedical research it is important to be able to view minute nanostructures, for example in carbon-fiber materials and bones. A team from the Technical University of Munich (TUM), the...

Der neue Mini-Teilchenbeschleuniger "Munich Compact Light Source" steht in Garching am Zentralinstitut für Medizintechnik (IMETUM). (Foto: K. Achterhold / TUM)

New state-of-the-art compact X-ray source

For some years now it has been possible to generate high-brilliance X-rays using ring-shaped particle accelerators (synchrotron sources). However, such installations are several hundred meters in diameter and cost billions...

Das weltweit erste Bild einer Fliege, die mit einem lasergestützten Röntgentomographie-Bildverfahren aufgenommen wurde. Zusammengesetzt ist es aus rund 1500 Einzelbildern. Es werden selbst feinste Details dreidimensional dargestellt. In einem konventionellen Röntgenbild würden sie unsichtbar bleiben. (Bild: S. Karsch und F. Pfeiffer / LMU, TUM)

Mini X-ray source with laser light

Researchers of the Max Planck Institute for Quantum Optics, the Technical University of Munich (TUM) and Ludwig-Maximilians-Universität München (LMU) have developed a miniature X-ray source with laser light. They used this...

Eine Plastikblume diente den Wissenschaftlern als Mikroskopierobjekt. (Bild: I. Zanette/TUM)

New simple setup for X-ray phase contrast

X-ray phase-contrast imaging can provide high-quality images of objects with lower radiation dose. But until now these images have been hard to obtain and required special X-ray sources whose properties are typically only...

Eine Kombination von Dunkelfeld- und konventionellem Röntgenbild ermöglicht eine klare Unterscheidung zwischen gesundem und emphysematösem Gewebe. Bild: Simone Schleede / TUM

Scattered X-rays reveal diseased tissue

Severe lung diseases are among the leading causes of death worldwide. To date they have been difficult to diagnose at an early stage. Within an international collaboration scientists from Munich now developed an X-ray...