Novel imaging device creates high-resolution 3D-x-rays of tiny velvet worm legs

Nano-CT device successfully tested

Computer Tomography (CT) is a standard procedure in hospitals, but so far, the technology has not been suitable for imaging extremely small objects. In PNAS, a team from the Technical University of Munich (TUM) describes a Nano-CT device that creates three-dimensional x-ray images at resolutions up to 100 nanometers. The first test application: Together with colleagues from the University of Kassel and Helmholtz-Zentrum Geesthacht the researchers analyzed the locomotory system of a velvet worm.

During a CT analysis, the object under investigation is x-rayed and a detector measures the respective amount of radiation absorbed from various angles. Three-dimensional images of the inside of the object can be constructed based on several such measurements. Up until now, however, the technology reached its limits when it came to objects as small as the tiny, 0.4 millimeter long legs of the velvet worm (Onychophora).

High-resolution images of this magnitude required radiation from particle accelerators, yet there are only a few dozen such facilities in Europe. Approaches suitable for the typical laboratory still had to struggle with low resolutions, or the samples investigated had to be made of certain materials and could not exceed a certain size. The reason was often the use of x-ray optics. Put simply, x-ray optics focus x-ray radiation similar to the way optical lenses focus light – but they also have several limitations.

High resolutions possible with new x-ray sources

The TUM Nano-CT system is based on a newly developed x-ray source, which generates a particularly focused beam, without relying on x-ray optics. In combination with an extremely low-noise detector, the device produces images that approach the resolution possible with a scanning electron microscope, while also capturing structures under the surface of the object under investigation.

“Our system has decisive advantages compared to CTs using x-ray optics,” says TUM scientist Mark Müller, lead author of the PNAS article. “We can make tomographies of significantly larger samples and we are more flexible in terms of the materials that can be investigated.”

Insights into the evolution of the arthropod world

Exactly these properties were ideal for the team led by Prof. Georg Mayer, head of the Department of Zoology at the University of Kassel. The scientists investigate the evolutionary origin of arthropods, including for example insects, spiders and crustaceans. Their current research, however, focuses on velvet worms (onychophorans), which can be thought of as worms with legs and are closely related to arthropods. Some velvet worm species can grow to a length of up to 20 centimeters, while others do not exceed 1 centimeter. The exact zoological classification of these ancient animals is still a matter of controversy; presumably, they share a common ancestor with arthropods and tardigrades (water bears).

“In contrast to arthropods, onychophorans do not have segmented limbs, as is also the case with their presumed common fossil ancestors,” says Georg Mayer. “The investigation of the functional anatomy of the velvet worm's legs plays a key role in determining how the segmented limbs of the arthropods evolved.” The Nano-CT images make it possible to investigate the individual muscle strands of the velvet worm leg. The team from Kassel plans to publish detailed results in the next few months. But they are already convinced about one thing: The Nano-CT device has passed its first practical test.

Nano-CT: Future applications in medicine

Like so many other imaging instruments, the Nano-CT system was developed and installed at the Munich School of BioEngineering (MSB). This TUM interdisciplinary research center is Europe's thematically most comprehensive university facility for the intersection of medicine, engineering sciences and natural sciences. Our goal in the development of the Nano-CT system is not only to be able to investigate biological samples, such as the leg of the velvet worm,” says Franz Pfeiffer, TUM Professor for Biomedical Physics, Director of the MSB, and a Fellow at the TUM Institute for Advanced Study (TUM-IAS).

“In the future, this technology will also make biomedical investigations possible. Thus, for example, we will be able to examine tissue samples to clarify whether or not a tumor is malignant. A non-destructive and three-dimensional image of the tissue with a resolution like that of the Nano-CT can also provide new insights into the microscopic development of widespread illnesses such as cancer.”

Publication:

M. Müller, I. de Sena Oliveira, S. Allner, S. Ferstl, P. Bidola, K. Mechlem, A. Fehringer, L. Hehn, M. Dierolf, K. Achterhold, B. Gleich, J. U. Hammel, H. Jahn, G. Mayer, F. Pfeiffer. “Myoanatomy of the velvet worm leg revealed by laboratory-based nanofocus X-ray source tomography”. PNAS (2017). DOI: 10.1073/pnas.1710742114

Further Information:

Munich School of BioEngineering

TUM Institute for Advanced Study

Nano-CT-imaging video (YouTube, 0.35 Min.)

Nano-CT-imaging video (extended version) (YouTube, ca. 3 Min.)

ContaCt:

Prof. Dr. Franz Pfeiffer
Chair of Biomedical Physics and Munich School of BioEngineering
Technical University of Munich
Tel.: +49 (89) 289 12551
franz.pfeiffer(at)tum.de

High-resolution images for journalists:

https://mediatum.ub.tum.de/1401200

Corporate Communications Center

Technical University of Munich

Article at tum.de

Links: Micro-CT-Aufnahme einer Mausniere, rechts: Nano-CT-Aufnahme des Gewebes.

Histology in 3D

To date, examining patient tissue samples has meant cutting them into thin slices for histological analysis. This might now be set to change – thanks to a new staining method devised by an interdisciplinary team from the...

Kalziumwellen – ein neuer Sensor verwandelt Licht in Schall, um Kalziumflüsse im Körper sichtbar zu machen. (Bild: B. van Rossum, G. Westmeyer / TUM)

Visible signals from brain and heart

Key processes in the body are controlled by the concentration of calcium in and around cells. A team from the Technical University of Munich (TUM) and the Helmholtz Zentrum München have developed the first sensor molecule...

Mit dem neuen "Open-Source"-Mikroskop NeuBtracker lassen sich Nervenaktivitäten während des natürlichen Bewegungsverhaltens von Zebrafischen beobachten. (Bild: A. Lauri / TUM)

Zebrafish live and in colour

A team of scientists from the Helmholtz Zentrum München and the Technical University of Munich (TUM) has successfully developed a new type of microscope. The so-called NeuBtracker is an open source microscope that allows to...

Hilfe für Kontaktlinsenträger mit trockenen Augen könnte eine Substanz aus dem Magen von Schweinen bringen, die auf die Linse aufgebracht wird. (Bild: istock / Koldunov)

Help from the stomach for dry eyes

After a long day of working at the computer, scratchy contact lenses are not only painful, over longer periods of time they can also damage ocular tissue. Relief may be in sight from a natural mucus component referred to as...

Leibniz-Preisträger Prof. Franz Pfeiffer und eine Wissenschafterin arbeiten an einem Projekt mit dem Mini-Teilchenbeschleuniger MuCLS.

Munich School of BioEngineering sets European standards

Two years after its founding at the Technical University of Munich (TUM), the Munich School of BioEngineering (MSB) is expanding its scope of action: The upcoming opening of the MSB-associated Central Institute for...

Prof. Franz Pfeiffer und PD Dr. Daniela Münzel am Mini-Synchrotron Munich Compact Light Source.

Miniature particle accelerator saves on contrast agents

The most prevalent method for obtaining images of clogged coronary vessels is coronary angiography. For some patients, however, the contrast agents used in this process can cause health problems. A team at the Technical...

Der neue Mini-Teilchenbeschleuniger "Munich Compact Light Source" steht in Garching am Zentralinstitut für Medizintechnik (IMETUM). (Foto: K. Achterhold / TUM)

New state-of-the-art compact X-ray source

For some years now it has been possible to generate high-brilliance X-rays using ring-shaped particle accelerators (synchrotron sources). However, such installations are several hundred meters in diameter and cost billions...