TUM – Technical University of Munich Menu
Links: Micro-CT-Aufnahme einer Mausniere, rechts: Nano-CT-Aufnahme des Gewebes.
Diese Aufnahmen wurden durch die neue Färbemethode möglich: Links: Micro-CT-Aufnahme einer Mausniere, rechts: Nano-CT-Aufnahme des Gewebes. (Bild: Müller, Pfeiffer / TUM / reproduced with permission from PNAS)
  • Research news

New staining method enables Nano-CT imaging of tissue samples

Histology in 3D

To date, examining patient tissue samples has meant cutting them into thin slices for histological analysis. This might now be set to change – thanks to a new staining method devised by an interdisciplinary team from the Technical University of Munich (TUM). This allows specialists to investigate three-dimensional tissue samples using the Nano-CT system also recently developed at TUM.

Tissue sectioning is a routine procedure in hospitals, for instance to investigate tumors. As the name implies, it entails cutting samples of body tissue into thin slices, then staining them and examining them under a microscope. Medical professionals have long dreamt of the possibility of examining the entire, three-dimensional tissue sample and not just the individual slices. The most obvious way forward here lies in computed tomography (CT) scanning – also a standard method used in everyday clinical workflows.

Previous limitations in resolution and contrast

Thus far, there have been two major hurdles to the realization of this goal. Firstly, the resolution of conventional CT scanners is too low. Today’s Micro- and Nano-CT systems are rarely suitable for use in frontline medicine. Some do not offer sufficiently high resolution, while others rely on radiation from large particle accelerators.

Secondly, soft tissue is notoriously difficult to examine using CT equipment. Samples have to be stained to render them visible in the first place. Stains for CT scanning are sometimes highly toxic, and they are also extremely time-consuming to apply. At times they modify the tissue to such an extent that further analysis is then impossible.

Successful collaboration between physics, chemistry and medicine

Now, however, scientists at TUM’s Munich School of BioEngineering (MSB) have solved both problems. In November 2017, Prof. Franz Pfeiffer and his team unveiled a Nano-CT system that delivers resolutions of up to 100 nanometers and is suitable for use in typical laboratory settings. In the current issue of the scientific journal PNAS, the cross-disciplinary research team from physics, chemistry and medicine also presents a staining method for histological examination with Nano-CT.

Using a mouse kidney, the scientists have successfully demonstrated that Nano-CT is able to generate 3D images that match the information granularity of tissue sections. At the core of the staining method lies eosin, a standard dye used in tissue sampling that was previously considered unsuitable for CT.

“Our approach included developing a special pre-treatment so that we can use eosin anyway,” outlines chemist Dr. Madleen Busse. The staining method is so time-efficient that it is also suited to everyday clinical workflows. “Another important benefit is that there are no problems using established methods to examine the tissue sample following the scan,” adds Busse.

Enhancement rather than replacement

In the next step, the researchers are looking to examine human tissue samples. However, CT histology is not set to replace conventional methods any time soon. For the moment, at least, the team views the new procedure as supplementary – for instance giving doctors additional insights into the three-dimensional distribution of cells and nuclei. Franz Pfeiffer also sees new opportunities here for basic medical research: “Alongside diagnostic applications, the non-destructive 3D examination enabled by Nano-CT could deliver new insights into the microscopic origins of widespread diseases such as cancer.”

 

Publication:

M. Busse, M. Müller, M. A. Kimm, S. Ferstl, S. Allner, K. Achterhold, J. Herzen, F. Pfeiffer, “Three-dimensional virtual histology enabled through cytoplasm-specific X-ray stain for microscopic and nanoscopic computed tomography”, PNAS (2018). DOI: 10.1073/pnas.1720862115

Further Information:

The Nano-CT system and staining method were developed at the Munich School of BioEngineering (MSB) This interdisciplinary TUM research center is Europe’s most multi-disciplinary university institution focused on the interface between medicine, engineering and natural sciences. Franz Pfeiffer, Professor of Biomedical Physics is Director of the MSB.

Contact:

Prof. Dr. Franz Pfeiffer
Chair of Biomedical Physics and Munich School of BioEngineering
Technical University of Munich
Tel.: +49 (89) 289 12551
franz.pfeiffer(at)tum.de

High-resolution images for journalists:

mediatum.ub.tum.de/1432531

Corporate Communications Center

Technical University of Munich

Article at tum.de

Gummi-Süßigkeiten mit aufgedruckten Mikroelektroden-Arrays.

Producing sensors with an inkjet printer

Microelectrodes can be used for direct measurement of electrical signals in the brain or heart. These applications require soft materials, however. With existing methods, attaching electrodes to such materials poses...

Kalziumwellen – ein neuer Sensor verwandelt Licht in Schall, um Kalziumflüsse im Körper sichtbar zu machen. (Bild: B. van Rossum, G. Westmeyer / TUM)

Visible signals from brain and heart

Key processes in the body are controlled by the concentration of calcium in and around cells. A team from the Technical University of Munich (TUM) and the Helmholtz Zentrum München have developed the first sensor molecule...

Ein Stummelfüßer der Art Euperipatoides rowelli.

Nano-CT device successfully tested

Computer Tomography (CT) is a standard procedure in hospitals, but so far, the technology has not been suitable for imaging extremely small objects. In PNAS, a team from the Technical University of Munich (TUM) describes a...

Mit dem neuen "Open-Source"-Mikroskop NeuBtracker lassen sich Nervenaktivitäten während des natürlichen Bewegungsverhaltens von Zebrafischen beobachten. (Bild: A. Lauri / TUM)

Zebrafish live and in colour

A team of scientists from the Helmholtz Zentrum München and the Technical University of Munich (TUM) has successfully developed a new type of microscope. The so-called NeuBtracker is an open source microscope that allows to...

Leibniz-Preisträger Prof. Franz Pfeiffer und eine Wissenschafterin arbeiten an einem Projekt mit dem Mini-Teilchenbeschleuniger MuCLS.

Munich School of BioEngineering sets European standards

Two years after its founding at the Technical University of Munich (TUM), the Munich School of BioEngineering (MSB) is expanding its scope of action: The upcoming opening of the MSB-associated Central Institute for...

Prof. Franz Pfeiffer und PD Dr. Daniela Münzel am Mini-Synchrotron Munich Compact Light Source.

Miniature particle accelerator saves on contrast agents

The most prevalent method for obtaining images of clogged coronary vessels is coronary angiography. For some patients, however, the contrast agents used in this process can cause health problems. A team at the Technical...

Der neue Mini-Teilchenbeschleuniger "Munich Compact Light Source" steht in Garching am Zentralinstitut für Medizintechnik (IMETUM). (Foto: K. Achterhold / TUM)

New state-of-the-art compact X-ray source

For some years now it has been possible to generate high-brilliance X-rays using ring-shaped particle accelerators (synchrotron sources). However, such installations are several hundred meters in diameter and cost billions...